dojo.md
University for AI agents. 92 courses, 4400+ scenarios, any model via OpenRouter. Auto-training loops generate per-model SKILL.md documents. Works with Claude Code, OpenClaw, Cursor, Windsurf. No fine-tuning req...
EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, and EUDAMED integration.
请根据来源仓库和你的 AI 工具说明安装此技能。先阅读技能文件和依赖要求,再添加到工作流。
SkillHub CLI
skillhub install alirezarezvani/mdr-745-specialist打开来源仓库,查看说明和兼容环境后,按来源提供的命令或步骤安装。
将来源链接提供给你的 Agent,让它先读取说明、核对依赖,并向你说明将执行的安装步骤。
EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.
Classify device under MDR Annex VIII:
| Factor | Class I | Class IIa | Class IIb | Class III |
|---|---|---|---|---|
| Duration | Any | Short-term | Long-term | Long-term |
| Invasiveness | Non-invasive | Body orifice | Surgical | Implantable |
| System | Any | Non-critical | Critical organs | CNS/cardiac |
| Risk | Lowest | Low-medium | Medium-high | Highest |
| Information Use | Condition Severity | Class |
|---|---|---|
| Informs decision | Non-serious | IIa |
| Informs decision | Serious | IIb |
| Drives/treats | Critical | III |
Example 1: Absorbable Surgical Suture
Example 2: AI Diagnostic Software
Example 3: Cardiac Pacemaker -...
这些信息来自收录时的来源分析,可能滞后;使用前请核对最新来源文件。
# MDR 2017/745 Specialist EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence. --- ## Table of Contents - [Device Classification Workflow](#device-classification-workflow) - [Technical Documentation](#technical-documentation) - [Clinical Evidence](#clinical-evidence) - [Post-Market Surveillance](#post-market-surveillance) - [EUDAMED and UDI](#eudamed-and-udi) - [Reference Documentation](#reference-documentation) - [Tools](#tools) --- ## Device Classification Workflow Classify device under MDR Annex VIII: 1. Identify device duration (transient, short-term, long-term) 2. Determine invasiveness level (non-invasive, body orifice, surgical) 3. Assess body system contact (CNS, cardiac, other) 4. Check if active device (energy dependent) 5. Apply classification rules 1-22 6. For software, apply MDCG 2019-11 algorithm 7. Document classification rationale 8. **Validation:** Classification confirmed with Notified Body ### Classification Matrix | Factor | Class I | Class IIa | Class IIb | Class III | |--------|---------|-----------|-----------|-----------| | Duration | Any | Short-term | Long-term | Long-term | | Invasiveness | Non-invasive | Body orifice | Surgical | Implantable | | System | Any | Non-critical | Critical organs | CNS/cardiac | | Risk | Lowest | Low-medium | Medium-high | Highest | ### Software Classification (MDCG 2019-11) | Information Use | Condition Severity | Class | |-----------------|-------------------|-------| | Informs decision | Non-serious | IIa | | Informs decision | Serious | IIb | | Drives/treats | Critical | III | ### Classification Examples **Example 1: Absorbable Surgical Suture** - Rule 8 (implantable, long-term) - Duration: > 30 days (absorbed) - Contact: General tissue - Classification: **Class IIb** **Example 2: AI Diagnostic Software** - Rule 11 + MDCG 2019-11 - Function: Diagnoses serious condition - Classification: **Class IIb** **Example 3: Cardiac Pacemaker** -...